Honeywell Thermostat Chronotherm Iii Instructions

  1. Honeywell Thermostat Chronotherm Iii Manual
  2. Honeywell Thermostat Chronotherm 111
  3. Honeywell Thermostat T8600 Chronotherm Iii Manual
  • Download Honeywell thermostat user manual by selecting the correct model. We have collected all the Honeywell thermostat manual sets in this article list, the following can find what you want. Honeywell Thermostat TH5220D1003 Manual; Honeywell Thermostat T7351F2010 Instructions Manual.
  • The Honeywell Chronotherm III uses three AAA batteries to power its digital display and store and run programmed settings. When the batteries require replacing, the display screen shows 'REPL BAT.' When you see this message, replace your batteries as soon as possible.
  • About the Honeywell Chronotherm III T8611 View the manual for the Honeywell Chronotherm III T8611 here, for free. This manual comes under the category Thermostat and has been rated by 1 people with an average of a 7.2.
Loading..

T8611G,R

Chronotherm III

Chronotherm iii t8611m - read user manual online or download in PDF format. Pages in total: 32.

Fuel SaverThermostats

Application

These thermostats provide energy saving control for a 24 Vac multistage heat pump heating/cooling system as indicated in Table 1 and are powered directly from the control transformer. All models have 5-1-1 programming.

As long as AC power is continuously available to transformer, the thermostat will be compatible with most control systems.

The T8611G,R models include SYSTEM and ENRG SAV LEDs near the top front of the thermostat. The SYSTEMLEDlightswhenthethermostatissignalingforheating or air conditioning. The ENGR SAV LED lights during the LEAVE and SLEEP periods.

TheAUX.HT.,EM.HT.,andCHECKLEDSarelocated nearthebottomcenterofthesubbase.SeeTable1.TheAUX. HT. LED lights whenever the thermostat is calling for operation of the backup or auxiliary heater. Backup (auxiliary)heatismoreexpensivetooperatethantheheatpumpand typicallyisusedonlywhentheheatpumpisunabletohandle the load. The EM. HT. LED lights whenever the thermostat system switch is in the EM. HT. position. The CHECK LED lights when something needs to be checked to maintain efficient operation of the system. Consult heat pump equipment literature to determine specific meaning of this LED.

Heat and cool anticipation is fixed in all models; no adjustment is necessary. Cycle rates are adjustable for auxiliary heating stage.

TABLE 1—Thermostat Models.

Thermostat

Stages

Switching

LEDs

Changeover

Terminals

Comments

See Fig.

Heat

Cool

System

Fan

T8611G

2

1

EM.HEAT-

ON-

EM.HT,

Auto

R, C/X, L,

4

HEAT-OFF-

AUTO

AUX.HT.

W2,E,G,O,

AUTO-COOL

B,Y,X2,X1

T8611R

2

1

EM.HEAT-

ON-

EM.HT.,

Manual

R,C/X,L,

5

HEAT-OFF-

AUTO

AUX.HT.

W2,E,W1,G,

COOL

O,B,Y,P

2

1

EM.HEAT-

ON-

EM.HT.

Manual

How to copy and paste clip studio paint pro. R,B,X,W2,

Exact

6

HEAT-OFF-

AUTO

E,W1,G,O,

replacement

COOL

H,Y1

for York

model no.

2ET11700224.

Installation

WHEN INSTALLING THIS PRODUCT..

1.Read these instructions carefully. Failure to allow them could damage the product or cause a hazardous condition.

2.Check the ratings on the product to make sure the product is suitable for your application.

3.Installermustbeatrained,experiencedservicetechni-

cian.

4.Allowthermostattowarmtoroomtemperaturebefore operating.

5.After installation is complete, check out product operation as provided in these instructions.

!CAUTION

1.Disconnect power supply to prevent electrical shock or equipment damage.

2.After wiring is complete, push excess wire back into the hole, and plug hole with nonhardening caulk, putty or insulation to prevent drafts from affecting thermostat operation.

LOCATION

Installthermostatandsubbaseabout5ft.[1.5m]abovethe floorinanareawithgoodaircirculationatroomtemperature.

Do not install the thermostat where it may be affected

J.H. • 3-92 • © Honeywell Inc. 1992 • Form Number 69-0348—1

by—

—drafts or dead spots behind doors, in corners or under cabinets.

—hot or cold air from ducts. —radiant heat from sun or appliances —concealed pipes and chimneys.

—unheated (uncooled) areas behind the thermostat, such as an outside wall.

IF REPLACING AN EXISTING THERMOSTAT

Turn off power to thermostat at furnace or heat pump. A two-transformersystemmayrequireturningofftwoswitches or disconnects. Remove any existing wallplate or subbase from the wall. Label or write down each wire color with the letterornumberonthewiringterminalasthewireisremoved, to avoid miswiring later.

IF NEW INSTALLATION

Runacabletoaholeattheselectedwalllocation,andpull about 3 in. [76 mm] of wire through the opening. Color- coded,8-gaugethermostatcablewithoneconductorforeach wiring terminal is recommended. Good service practice recommends selecting cable with one or two more conductors than the immediate application requires.

MOUNTING SUBBASE

The subbase does not require leveling for proper operation, but for appearance only.

Remove thermostat from subbase, see Fig. 1.

Thesubbasemountsdirectlyontothewallwiththescrews included in the package. Use the subbase as a template, and with a pencil, mark the two mounting screw positions, see Fig. 2. Use 3/16 in. bit to drill holes for anchors. Gently tap anchors into holes until they are flush with the wall surface. Threadwiresthroughthecenteropeningofthesubbase.Then mountthesubbaseusingtwoscrewsprovided.Gentlytighten screws level top surface of subbase, then securely tighten screws.

Fig. 1—Removing thermostat from subbase.

SYSTEM

EM. HT. HEAT OFF

AUTO COOL

FAN

ON

AUTO

AUX. HEAT

CHECK

M5179A

Fig. 2—Mounting subbase on wall.

WALL

WIRES THROUGH

WALL

WALL OPENING

ANCHORS

(2)

MOUNTING

HOLES

MOUNTING

SCREWS (2)

SUBBASE

M5175

WIRING

All wiring must comply with local electrical codes and ordinances.

Disconnect power before wiring to prevent electrical shock or equipment damage.

The shape of the terminal barrier permits insertion of straight or conventional wraparound wiring connections. Either method is acceptable.

Refer to Figs. 4-6 for typical hookups of subbase and thermostat.

NOTE: Keep all wiring restricted to ribbed area surrounding terminals to assure thermostat/subbase contact, see Fig. 3.

Fig. 3—Keep wiring restricted to ribbed area surrounding terminals.

FOR STRAIGHT INSERTION –

STRIP 5/16 in. [8 mm]

RESTRICT

WIRING TO

FOR WRAPAROUND –

THIS AREA

STRIP 7/16 in. [11 mm]

FRONT VIEW OF

TERMINAL AREA

WIRING TO BE BELOW

TOP SURFACE

THIS SURFACE

OF SUBBASE

CROSS-SECTIONAL VIEW OF

TERMINAL AREA

M3062

Fig. 4—T8611G 2-stage heat/1-stage cool thermostat.

1

L1 L2 (HOT)

R

HIGH

LIMIT

C/X

EM. HEAT

AUX. HEAT

LED (RED)

LED (GRN)

FAN

L

SWITCH

MONITOR

ON

W2

SUBBASE

THERMOSTAT

AUTO

HEAT 2

AUXILIARY

LOGIC/

LOGIC

CONTROL

HEAT RELAY

CIRCUIT

CIRCUIT

E

EMERGENCY

HEAT RELAY

SYSTEM

SWITCH

EM. HT.

HEAT

G

FAN RELAY

OFF

C.O.

AUTO

O

COOL

CHANGEOVER

C.O.

RELAY (COOL)

Cs5

HIGH

B

LIMIT

HEAT 1

COOL

CHANGEOVER

RELAY (HEAT)

Y

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

X1

2

DENOTES THERMOSTAT TO SUBBASE INTERCONNECT.

CHECK LED

3

(YELLOW)

3 POSSIBLE CHECK LED CIRCUITS:

X2

X1

TO R

X1

TO R

X1

L1

CHECK

FAULT DETECTION

CHECK

FAULT DETECTION

CHECK

SWITCHING

(HOT)

LED

LED

LED

SWITCH

DEVICE

1

(YELLOW)

(YELLOW)

SWITCH

(YELLOW)

X2

24 Vac

TO C/X

X2

TO C/X

X2

L2

SWITCH TO R (POWER) SIDE OF

SWITCH TO C (COMMON) SIDE

SWITCH IN SECONDARY OF

SYSTEM TRANSFORMER

SEPARATE TRANSFORMER

OF SYSTEM TRANSFORMER

3

69-0348—1

Download Operation & user’s manual of Honeywell CHRONOTHERM III T8611M Heat Pump, Thermostat for Free or View it Online on All-Guides.com.

Brand: Honeywell

Category: Heat Pump , Thermostat

Type: Operation & user’s manual for Honeywell CHRONOTHERM III T8611M

Pages: 32 (0.33 Mb)

CONTENTS
Specifications......................... 2
Ordering Information................... 2
Selection/Application................... 5
Installation.......................... 12
Checkout............................ 18
Programming The Thermostat ........... 20
Operating The Thermostat .............. 25
Operation........................... 27
Troubleshooting...................... 29
Glossary............................ 30
Table of Contents..................... 32
(7-Day Programming)
Heat Pump Thermostats
Thermostat provides automatic control of multi-
highest standard of comfort and convenience
Full seven-day program capability; different sched-
Can be programmed in hand (with batteries in-
stalled) or on the wall to provide up to four tem-
Large digital clock (liquid crystal display) indi-
rent period and room temperature.

Honeywell Thermostat Chronotherm Iii Manual

perature to programmed temperature at program-

Honeywell Thermostat Chronotherm 111

ings.
ture within 1° F of setpoint.
Honeywell
—WARMER and COOLER keys.
—CHANGE to last period key.
override (vacation/holiday).
Installer self-test with time delay override saves
SYSTEM light-emitting diode (LED) on thermo-
AUX. HT., EM. HT., CHECK LEDs available on
Automatic heat/cool changeover.
Batteries included provide power to maintain clock
Switching subbase with wiring terminals included.
Model available with separate sensor for remote
C. H. • Rev. 10-92 • ©Honeywell Inc. 1992 • Form Number 68-0076—1